Home / All / Circuit Breaker / Economic 4.5KA, 6kA Regular Series Circuit Breaker /

6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker

6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker

6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker
6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker6kA JVL7 240V Sofielec Magnetic 100A 125A RCCB 2P 4P, SEMKO,CB,CE approval, A,AC type Residual Current Circuit Breaker
CategoriesEconomic 4.5KA, 6kA Regular Series Circuit Breaker
Modeelectro-magnetric type. elecronic type
Residual current charatrsticsA AC
Pole No2, 4
Rated making and breaking capacity630A
Rated current(A)25, 40, 63, 80, 100, 125
Rated voltageAC 230(240)/400(415)
Rated frequency50/60Hz
Rated conditional short-circuit current Inc6kA
Terminal Connection Height21mm
Protection classlP20
Update TimeApr 27,2024
Detail Information
Technical Data 

Mode: electro-magnetic type, electronic type

Residual current characteristics: A, AC

Pole No.: 2, 4

Rated making and breaking capacity:  630A

Rated current(A): 25, 40, 63, 80, 100, 125

Rated voltage: AC 230(240)/400(415)

Rated frequency: 50/60Hz

Rated residual operating current I△n(A): 0.03, 0.1, 0.3, 0.5

Rated residual non operating current I△no: 0.5I△n

Rated conditional short-circuit current Inc: 6kA

Rated conditional residual short-circuit Current I△c: 6kA

Tripping duration: instantaneous tripping≤0.1s

Residual tripping current range: 0.5I△n~I△n

Electro-mechanical endurance: Not less than 4000

Connection capacity: Rigid conductor 35mm ²

Terminal Connection Height: 21mm

Connection terminal:Pillar terminal with clamp

Fastening torque: 2.5Nm

Installation:On symmetrical DIN rail 35mm

Panel mounting


Protection class:IP20

Construction and Feature 







Provides protection against earth fault/leakage current and function of isolation

High short-circuit current withstand capacity

Applicable to terminal and pin/fork type busbar connection

Contact position indication

Equipped with finger protected connection terminals

Fire resistant plastic parts endures abnormal heating and strong impact

Automatically disconnect the circuit when earth fault/ leakage current occurs and

exceeds the rated sensitivity.

Independent of power supply and line voltage, and free from external interference,voltage fluctuation.

Overall & Installation Dimensions

Wiring Diagram